Current-flow null

Untested

Force should appear with negligible leakage current. If high I correlates with high F, you're measuring corona.

Current validation status

Result: untested

Requires leakage current data

What this test isolates

Premise. An electrostatic stack draws displacement current only — leakage I ≈ 0 in a healthy dielectric. Force-from-current means ion wind.

Why it matters. The single most direct discriminator between electrostatic and ion-wind explanations of measured thrust.

Variable. Leakage current I (µA)

Hold constant

  • Standard run; add a current monitor in the HV return path

Prediction. F is independent of I to within 20% across the test range.

How to run this test

  1. 1

    Insert a current shunt

    100 kΩ on the HV-return / ground side, scope across it for V→I.

  2. 2

    Run a V sweep

    Capture both F and I at 5 voltages.

  3. 3

    Plot F vs I

    Independence (flat curve, lots of scatter) = framework. Linear correlation = corona.

Pitfalls

  • !Probe RC artifacts at HV — calibrate the shunt before claiming a null.
  • !Stray surface leakage masquerades as the real signal.